276°
Posted 20 hours ago

Apollo Ultrasonic Füllstands-Sensor Standard Standard Betriebsspannung (Bereich): 150-250 V/AC 1S

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

The receiver unit displays the level of fuel inside the tank, via an easy to read LCD display, which usefully includes a low level warning alert. The Apollo is suitable to operate in temperatures of -10 to +60°C. Temperatures below or above these stated may cause the unit to malfunction, but on return to normal climate conditions, the Apollo will revert to correct reading. Direct Cylinders Direct Unvented Cylinders Slimline Direct Unvented Cylinders Indirect Cylinders Indirect Unvented Slimline Indirect Unvented More Indirect Cylinders Is there an obstruction restricting the signal in the tank, this could include the location of the transmitter on the tank. Ideal for monitoring heating oil and diesel – but suitable too for a wide range of liquids including admixtures, agricultural fuel oil, anti-freeze, biodiesel, bio heating oil, fuel oil, detergents, lubricants, waste oil and water. Range

The Apollo Smart is suitable for use with storage tanks that fit within the limits in the adjacent table (these apply to the inner tank for Bunded tanks) Apollo Ultrasonic Smart Oil Tank Level Monitor is designed specifically for domestic oil heating installations. If a fixed triangle appears on the receiver screen, it indicates that the lithium battery in the transmitter is running low. The receiver will continue to give level readings until the battery is exhausted. Replace the battery as soon as possible. (3 Volt – CR2430)

Product Options

Tanks should only be filled to 95% of their brimful capacity. In the event that the tank is filled to the top, this will not harm the transmitter as it is a sealed unit. If the tank is filled to the top as described then the oil/liquid will be too close to the underside of the transmitter and will result in incorrect readings or a flashing triangle error on the receiver device. When the oil/liquid level drops to 100 – 120 mm from the top of the tank, the readings will return to normal without any adjustments or action needed. Adblue Pumps & Gravity Kits AdBlue Hand Pumps AdBlue 230v 12v & 24v Electric Transfer Pumps AdBlue 12v Transfer Pumps AdBlue 24v Transfer Pumps AdBlue Hoses And Accessories This gives me about 4 volts output from the 78L05A 5 volt regulator chip. It's a bit low but it's enough to work the unit. This indicates no ultrasonic echo is being received from the liquid surface. Ensure the bottom of the transmitter is clear from dirt or moisture. In some cases, a white chalky residue can build up on the cone of the device. Take the transmitter off the tank and clean this off, then refit it to the top of the tank. One size fits all. The Apollo Ultrasonic is suitable for almost any tank up to 3 metres tall, irrespective of manufacturer, capacity or material of construction.

Q2. I have lost the instructions how do I rematch the unit and how do I know what Pin settings to set on the rear of the receiver plug.Q19. What if the oil in the tank is full to the very top, will this harm the Apollo transmitter and will I receive a correct reading? One size fits all. The Apollo Ultrasonic is suitable for almost any tank up to 3 metres tall, irrespective of manufacturer, capacity or material of construction

The integrated oil tank alarm sounds when the oil level reaches a low status to alert the user that they need a fuel delivery, as well as sounding if the tank contents drop suddenly indicating a potential theft.No, as you have not used any oil, the level of oil has remained constant thus the monitor has received the same reading. Upon using your oil again, the unit will update the Days to empty again. Note depending on your oil usage, this may take up to 1 week. If the tank is filled to the top as described then the oil/liquid will be too close to the underside of the transmitter and will result in intermittent incorrect readings or Errors until the oil/liquid level drops to 100 – 120 mm from the top of the tank. The readings will then return to normal without any adjustments or action needed. Please note depending on oil usage this may take a couple of weeks.The reason for the foregoing is that the Ultrasonics bounces a sound from the surface of the oil/liquid and measures the time it takes to then give a reading but if the oil/liquid is too close then it cannot record a time, it, therefore, needs a distance of 100 – 120 mm to give a correct. Flow Meters Fuel Nozzles Fuel Filters Fuel Management Systems Diesel Hoses Gravity Hoses Hose Reels Fuel Treatment Isolation Valves This might open up the possibility to match a transmitter and receiver when the transmitter is already installed in the tank.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment